EquipmentLocator.com

Yoder & Frey May 9th Auction, Houston, TEXAS

No Image
Einzelheiten
Modell:
ATC480500K
Vorgesehene Betriebsstunden:
0
Anmerkungen
PGS-500 POWER CONDITIONER EQUIPPED PER THE BELOW: - 500KVAR 9 STEPS OF 50KVAR/ 2 STEPS OF 25KVAR 480V - ON-BOARD MAIN CIRCUIT BREAKER - TX2 - MULTI-TAP SPLIT CORE CURRENT TRANSFORMER - APPLICATION FOR SERVICE ENTRANCE POWER FACTORCORRECTION INSTALLATION REQUIRING PRECISE MAINTENANCE OF TARGET POWER FACTOR - CABINET IS 12 GAUGE STEEL WITH ANSI 61 GREY POWDER FINISH LIFT BOLTS STANDARD NEMA 1 - POWER LINE INTERCONNECT: RUGGED COPPER BUS BAR CONNECTION WITH ACCESS PROVIDED FOR TOP OR BOTTOM ENTRY. BUS BARS ARE BRACED FOR 65KAIC AT 600V. ALL INTERNAL POWER WIRING CONNECTIONS FROM BUS ARE LAID OUT ON A MOST DIRECT BASIS WITH MINIMUM BENDS FOR EASE OF TROUBLESHOOTING - MODULARTRAY DESIGN: CAPACITOR BANKS ARRANGED IN MODULAR TRAYS WITH CAPACITORS FUSES - BLOWN FUSE INDICATING LIGHTS AND CONTACTORS GROUPED IN A LOGICAL EASILY UNDERSTOOD LAYOUT. - FUSING: UL RECOGNIZED 200 000A INTERRUPTING CAPACITY PROVIDED ON ALL THREE PHASES OF EACH BANK. BLADE-TYPE FUSES MOUNTED ON INSULATOR STAND-OFFS. - BLOWN FUSE INDICATOR LIGHTS - PUSH TO TEST - AUTO LOCATE: WHEN DOOR IS OPEN AND BUS ENERGIZED FUSE CIRCUIT AUTOMATICALLY CHECKS FOR CLEARED FUSES. - DOOR INTERLOCK: AUTOMATICALLY TURNS OFF CONTROL CIRCUIT WHEN ENGAGED. POWER CONTINUES TO BE PROVIDED TO THE UNIT UNTIL DISCONNECT IS OPEN. - EXHAUST FAN: TWO FANS PER CABINET PROVIDE THERMAL PROTECTION. DUST FILTERING PROVIDED. - EASE OF EXPANSION: CAPACITOR STAGE NESTS ARE SELF-CONTAINED AND CAN BE ADDED IN THE FIELD - EASE OF REPLACEMENT: CELLS CAN BE EASILY INDIVIDUALLY REPLACED BY REMOVING THE MOUNTING BOLT AND LIFTING OUT OF THE NEXT WITHOUT REMOVAL OF ANY OTHER COMPONENTS - CONTROLLER FEATURES: DIGITAL DISPLAY OF POWER FACTOR & NUMBER OF ENERGIZED BANKS VISUAL INDICATION OF INSUFFICIENT KVAR TO REACH TARGET POWER FACTOR CAPACITORS DISABLED IN STEPSWITHIN 35 MSEC OF MAIN POWER INTERRUPTION AUTOMATIC DETECTION AND CORRECTION OF CT AND PHASE POLARITY PROVIDED PROTECTION AGAINST OVERVOLTAGE OVERTEMPERATURE AND HARMONIC OVERLOAD EVENTS - CONTACTOR FULLY RATED FOR CAPACITOR SWITCHING UP TO 60KVAR AT 600V - CONTACTOR INTEGRAL PRE-CHARGE/PRE-INSERTION MODULE STANDARD - FIVE-YEAR WARRANTY OF COMPONENTS.

2021 Other ATC480500K

Gebraucht
Generator
Verkauf
Für Preis anfragen

Vertriebskontakte

Einzelheiten
Modell:
ATC480500K
Vorgesehene Betriebsstunden:
0
Anmerkungen
PGS-500 POWER CONDITIONER EQUIPPED PER THE BELOW: - 500KVAR 9 STEPS OF 50KVAR/ 2 STEPS OF 25KVAR 480V - ON-BOARD MAIN CIRCUIT BREAKER - TX2 - MULTI-TAP SPLIT CORE CURRENT TRANSFORMER - APPLICATION FOR SERVICE ENTRANCE POWER FACTORCORRECTION INSTALLATION REQUIRING PRECISE MAINTENANCE OF TARGET POWER FACTOR - CABINET IS 12 GAUGE STEEL WITH ANSI 61 GREY POWDER FINISH LIFT BOLTS STANDARD NEMA 1 - POWER LINE INTERCONNECT: RUGGED COPPER BUS BAR CONNECTION WITH ACCESS PROVIDED FOR TOP OR BOTTOM ENTRY. BUS BARS ARE BRACED FOR 65KAIC AT 600V. ALL INTERNAL POWER WIRING CONNECTIONS FROM BUS ARE LAID OUT ON A MOST DIRECT BASIS WITH MINIMUM BENDS FOR EASE OF TROUBLESHOOTING - MODULARTRAY DESIGN: CAPACITOR BANKS ARRANGED IN MODULAR TRAYS WITH CAPACITORS FUSES - BLOWN FUSE INDICATING LIGHTS AND CONTACTORS GROUPED IN A LOGICAL EASILY UNDERSTOOD LAYOUT. - FUSING: UL RECOGNIZED 200 000A INTERRUPTING CAPACITY PROVIDED ON ALL THREE PHASES OF EACH BANK. BLADE-TYPE FUSES MOUNTED ON INSULATOR STAND-OFFS. - BLOWN FUSE INDICATOR LIGHTS - PUSH TO TEST - AUTO LOCATE: WHEN DOOR IS OPEN AND BUS ENERGIZED FUSE CIRCUIT AUTOMATICALLY CHECKS FOR CLEARED FUSES. - DOOR INTERLOCK: AUTOMATICALLY TURNS OFF CONTROL CIRCUIT WHEN ENGAGED. POWER CONTINUES TO BE PROVIDED TO THE UNIT UNTIL DISCONNECT IS OPEN. - EXHAUST FAN: TWO FANS PER CABINET PROVIDE THERMAL PROTECTION. DUST FILTERING PROVIDED. - EASE OF EXPANSION: CAPACITOR STAGE NESTS ARE SELF-CONTAINED AND CAN BE ADDED IN THE FIELD - EASE OF REPLACEMENT: CELLS CAN BE EASILY INDIVIDUALLY REPLACED BY REMOVING THE MOUNTING BOLT AND LIFTING OUT OF THE NEXT WITHOUT REMOVAL OF ANY OTHER COMPONENTS - CONTROLLER FEATURES: DIGITAL DISPLAY OF POWER FACTOR & NUMBER OF ENERGIZED BANKS VISUAL INDICATION OF INSUFFICIENT KVAR TO REACH TARGET POWER FACTOR CAPACITORS DISABLED IN STEPSWITHIN 35 MSEC OF MAIN POWER INTERRUPTION AUTOMATIC DETECTION AND CORRECTION OF CT AND PHASE POLARITY PROVIDED PROTECTION AGAINST OVERVOLTAGE OVERTEMPERATURE AND HARMONIC OVERLOAD EVENTS - CONTACTOR FULLY RATED FOR CAPACITOR SWITCHING UP TO 60KVAR AT 600V - CONTACTOR INTEGRAL PRE-CHARGE/PRE-INSERTION MODULE STANDARD - FIVE-YEAR WARRANTY OF COMPONENTS.
Händlerseite anzeigen

General Aggregate Equipment Sales

Adresse
841 Oak Point Highway
Winnipeg, Manitoba R3C 2E6
Kanada
DirectLine: 204-697-9600
Fax: (204) 633-0955
Gesprochene Sprachen: English
Verfügbarkeit und Preis, vorbehaltlich von Änderungen und vorzeitigem Verkauf.

Teilen

SMS
Email
Facebook
Twitter
Pinterest
reddit
Tumblr
WhatsApp
Blogger
More

Preisumrechnung

Dies ist eine höfliche Preisumrechnung. Es ist möglicherweise nicht genau, da sich die Währungsumrechnungskurse ändern. Beim Kauf wird der Originalpreis in der Landeswährung impliziert.

Kontakt-Händler


Felder, die mit einem Sternchen (*) versehen sind, müssen ausgefüllt werden.

Preis Alarm


Abonnieren Sie, um über Preisänderungen dieses Artikels informiert zu werden.

Send us a message (optional)
Sprachen
North America
English Español Français
Latin America
English Español Português
Asia Pacific
English 中文