PGS-500 POWER CONDITIONER EQUIPPED PER THE BELOW: - 500KVAR 9 STEPS OF 50KVAR/ 2 STEPS OF 25KVAR 480V - ON-BOARD MAIN CIRCUIT BREAKER - TX2 - MULTI-TAP SPLIT CORE CURRENT TRANSFORMER - APPLICATION FOR SERVICE ENTRANCE POWER FACTORCORRECTION INSTALLATION REQUIRING PRECISE MAINTENANCE OF TARGET POWER FACTOR - CABINET IS 12 GAUGE STEEL WITH ANSI 61 GREY POWDER FINISH LIFT BOLTS STANDARD NEMA 1 - POWER LINE INTERCONNECT: RUGGED COPPER BUS BAR CONNECTION WITH ACCESS PROVIDED FOR TOP OR BOTTOM ENTRY. BUS BARS ARE BRACED FOR 65KAIC AT 600V. ALL INTERNAL POWER WIRING CONNECTIONS FROM BUS ARE LAID OUT ON A MOST DIRECT BASIS WITH MINIMUM BENDS FOR EASE OF TROUBLESHOOTING - MODULARTRAY DESIGN: CAPACITOR BANKS ARRANGED IN MODULAR TRAYS WITH CAPACITORS FUSES - BLOWN FUSE INDICATING LIGHTS AND CONTACTORS GROUPED IN A LOGICAL EASILY UNDERSTOOD LAYOUT. - FUSING: UL RECOGNIZED 200 000A INTERRUPTING CAPACITY PROVIDED ON ALL THREE PHASES OF EACH BANK. BLADE-TYPE FUSES MOUNTED ON INSULATOR STAND-OFFS. - BLOWN FUSE INDICATOR LIGHTS - PUSH TO TEST - AUTO LOCATE: WHEN DOOR IS OPEN AND BUS ENERGIZED FUSE CIRCUIT AUTOMATICALLY CHECKS FOR CLEARED FUSES. - DOOR INTERLOCK: AUTOMATICALLY TURNS OFF CONTROL CIRCUIT WHEN ENGAGED. POWER CONTINUES TO BE PROVIDED TO THE UNIT UNTIL DISCONNECT IS OPEN. - EXHAUST FAN: TWO FANS PER CABINET PROVIDE THERMAL PROTECTION. DUST FILTERING PROVIDED. - EASE OF EXPANSION: CAPACITOR STAGE NESTS ARE SELF-CONTAINED AND CAN BE ADDED IN THE FIELD - EASE OF REPLACEMENT: CELLS CAN BE EASILY INDIVIDUALLY REPLACED BY REMOVING THE MOUNTING BOLT AND LIFTING OUT OF THE NEXT WITHOUT REMOVAL OF ANY OTHER COMPONENTS - CONTROLLER FEATURES: DIGITAL DISPLAY OF POWER FACTOR & NUMBER OF ENERGIZED BANKS VISUAL INDICATION OF INSUFFICIENT KVAR TO REACH TARGET POWER FACTOR CAPACITORS DISABLED IN STEPSWITHIN 35 MSEC OF MAIN POWER INTERRUPTION AUTOMATIC DETECTION AND CORRECTION OF CT AND PHASE POLARITY PROVIDED PROTECTION AGAINST OVERVOLTAGE OVERTEMPERATURE AND HARMONIC OVERLOAD EVENTS - CONTACTOR FULLY RATED FOR CAPACITOR SWITCHING UP TO 60KVAR AT 600V - CONTACTOR INTEGRAL PRE-CHARGE/PRE-INSERTION MODULE STANDARD - FIVE-YEAR WARRANTY OF COMPONENTS.

2021 Other ATC480500K

Matériel d'occasion
Générateur
Vente
Appeler pour prix

Contacts commerciaux

Informations
Modèle:
ATC480500K
Nombre Heures:
0
Remarques
PGS-500 POWER CONDITIONER EQUIPPED PER THE BELOW: - 500KVAR 9 STEPS OF 50KVAR/ 2 STEPS OF 25KVAR 480V - ON-BOARD MAIN CIRCUIT BREAKER - TX2 - MULTI-TAP SPLIT CORE CURRENT TRANSFORMER - APPLICATION FOR SERVICE ENTRANCE POWER FACTORCORRECTION INSTALLATION REQUIRING PRECISE MAINTENANCE OF TARGET POWER FACTOR - CABINET IS 12 GAUGE STEEL WITH ANSI 61 GREY POWDER FINISH LIFT BOLTS STANDARD NEMA 1 - POWER LINE INTERCONNECT: RUGGED COPPER BUS BAR CONNECTION WITH ACCESS PROVIDED FOR TOP OR BOTTOM ENTRY. BUS BARS ARE BRACED FOR 65KAIC AT 600V. ALL INTERNAL POWER WIRING CONNECTIONS FROM BUS ARE LAID OUT ON A MOST DIRECT BASIS WITH MINIMUM BENDS FOR EASE OF TROUBLESHOOTING - MODULARTRAY DESIGN: CAPACITOR BANKS ARRANGED IN MODULAR TRAYS WITH CAPACITORS FUSES - BLOWN FUSE INDICATING LIGHTS AND CONTACTORS GROUPED IN A LOGICAL EASILY UNDERSTOOD LAYOUT. - FUSING: UL RECOGNIZED 200 000A INTERRUPTING CAPACITY PROVIDED ON ALL THREE PHASES OF EACH BANK. BLADE-TYPE FUSES MOUNTED ON INSULATOR STAND-OFFS. - BLOWN FUSE INDICATOR LIGHTS - PUSH TO TEST - AUTO LOCATE: WHEN DOOR IS OPEN AND BUS ENERGIZED FUSE CIRCUIT AUTOMATICALLY CHECKS FOR CLEARED FUSES. - DOOR INTERLOCK: AUTOMATICALLY TURNS OFF CONTROL CIRCUIT WHEN ENGAGED. POWER CONTINUES TO BE PROVIDED TO THE UNIT UNTIL DISCONNECT IS OPEN. - EXHAUST FAN: TWO FANS PER CABINET PROVIDE THERMAL PROTECTION. DUST FILTERING PROVIDED. - EASE OF EXPANSION: CAPACITOR STAGE NESTS ARE SELF-CONTAINED AND CAN BE ADDED IN THE FIELD - EASE OF REPLACEMENT: CELLS CAN BE EASILY INDIVIDUALLY REPLACED BY REMOVING THE MOUNTING BOLT AND LIFTING OUT OF THE NEXT WITHOUT REMOVAL OF ANY OTHER COMPONENTS - CONTROLLER FEATURES: DIGITAL DISPLAY OF POWER FACTOR & NUMBER OF ENERGIZED BANKS VISUAL INDICATION OF INSUFFICIENT KVAR TO REACH TARGET POWER FACTOR CAPACITORS DISABLED IN STEPSWITHIN 35 MSEC OF MAIN POWER INTERRUPTION AUTOMATIC DETECTION AND CORRECTION OF CT AND PHASE POLARITY PROVIDED PROTECTION AGAINST OVERVOLTAGE OVERTEMPERATURE AND HARMONIC OVERLOAD EVENTS - CONTACTOR FULLY RATED FOR CAPACITOR SWITCHING UP TO 60KVAR AT 600V - CONTACTOR INTEGRAL PRE-CHARGE/PRE-INSERTION MODULE STANDARD - FIVE-YEAR WARRANTY OF COMPONENTS.
Voir la page du concessionnaire

General Aggregate Equipment Sales

Adresse
841 Oak Point Highway
Winnipeg, Manitoba R3C 2E6
Canada
DirectLine: 204-697-9600
Fax: (204) 633-0955
Langues parlées: English
Disponibilité et prix sujet au changement et/ou à la vente antérieure.

Partager

SMS
Email
Facebook
Twitter
Pinterest
reddit
Tumblr
WhatsApp
Blogger
More

Conversion de prix

Il s'agit d'une conversion de prix de courtoisie. Il peut ne pas être exact car les taux de conversion des devises changent. Lors d'un achat, le prix d'origine dans la devise locale est implicite.

Revendeur à Contacter


Les champs marqués d'un * (astérisque) sont obligatoires.

Alerta Prix


Abonnez-vous pour être informé des changements de prix sur cet article.

Send us a message (optional)
Langues
North America
English Español Français
Latin America
English Español Português
Asia Pacific
English 中文